Model BD-5000 Intelligent Syringe Pump Manufacturer
Unique Functions:
1) User-friendly Anti-slip design, Big color LCD screen display; 2) Suitable for all brands of standard syringes: 5ml, 10ml, 20ml, 30ml and 50ml, 60ml; 3) Three kinds of injection modes: Rate mode, time mode and body weigh mode; 4) Pressure is detected directly and accurately by pressure sensor; 5) Language selection function: English, Turkish, Chinese and spcial request; 6) Double CPU monitoring to make the injection process safer and more reliable; 7) With Audio-Visual alarm and various alarm status shown; 8) With bolus (fast speed) dosage function; 9) Driven by precise step motor, no pulse wave occurs even during low rate.
Specifications: |
Product model |
Syringe Pump (Model: BD-5000) |
Maxim. Injection rate |
1500 ml/h (Different syringes have different maximum rate) |
Range of Flow Rate |
5 ml syringe: 0.1-100ml/h 10 ml syringe: 0.1-200 ml/h 20 ml syringe: 0.1-400 ml/h 30 ml syringe: 0.1-600 ml/h 50 ml syringe: 0.1-1500 ml/h |
Injection increment |
0.1ml |
Bolus rate |
5 ml syringe: 100ml/h 10 ml syringe: 200 ml/h 20 ml syringe: 400 ml/h 30 ml syringe: 400-600 ml/h 50 ml syringe: 400-1500 ml/h |
Injection Mode |
Rate mode, Time mode, Body Weight mode |
Rate mode |
Rate: 0.1-1500.0ml/h (the maximum value depends on the syringe size) |
Time mode |
Time: 1-2000 minutes; Volume limit: 0.1-999.9 ml |
Body Weight mode |
Body weight: 0.1-300.0 kg Drug limit: 0.1-999.9 mg Volume limit: 0.1-999.9 ml Dose: 0.1-9999.9 (depending on unit, dose, solution, weight and syringe size) Unit: mg/kg/h, ug/kg/min |
KVO rate |
Adjustable range: 0.1-5.0ml/h; Pressing STOP key to cancel the KVO function when it is unnecessary in use. |
IP Grade |
IPX1 |
Injection pressure |
The maximum pressure is 0.3Mpa,the occlusion alarm pressure value is 40kPa-160kPa. When the pressure value is minimum the injection rate is 25ml/h, and the longest occlusion alarm time is 10 minutes. When the pressure value is the minimum and the injection rate is 5ml/h, the longest alarm time is 10 minutes. |
Preset volume range |
0.1-9999.9 ml |
Preset time range |
0-99hours59minutes |
Accumulated volume display |
0.1-9999.9 ml |
Injection accuracy |
±3% (up to 2% after being adjusted) |
Power supply |
AC 100-240V , 50/60 Hz |
Battery |
Rechargeable lithium polymer battery, 7.4V, 1600mAh |
Maximum Power Consumption |
25VA, running more than 2 hours at the rate of 25ml/h after being fully charged. |
Battery Charge |
When the syringe pump is connected to AC power, the battery will automatically be recharged. (It takes more than 8 hours to fully recharge the battery.) |
Fuse |
2pcs of 250V 2A |
Displayed information |
Flow rate, accumulated injection volume, syringe specification, battery capacity, bed No., AC power indicator, operation indicator, etc. |
Status indication |
Stop, inject, bolus, KVO (stop flashing, the other indicators flash by turns.) |
Alarm |
Near, over, occlusion, low battery, abnormal 1 (communications failure), abnormal 2 (pump stuck), abnormal 3 (wrong parameters), volume limited alarm, no AC power, Alarm: |
Electronic memory time |
10 years |
Maximum Size of the Outer Shell |
280 mm×130 mm×120mm(length×width×height) |
Maximum Weight |
Less than 3.0 kg |
Classification |
Class II, Type BF |
Shell material |
ABS Plastic |
Operating Conditions |
Environment temperature: 5 degrees~40 degrees; air pressure: 86kPa ~106kPa; relative humidity ≤80% |
Storage Conditions |
Environment temperature: -40 degrees~55 degrees; air pressure: 50kPa~106kPa; relative humidity ≤95% |
Applicable Syringes |
National standard syringes: 5ml, 10 ml, 20 ml, 30ml and 50 ml |
Applicable Standard |
GB/T191-2008 GB8368-2005 GB9706.1-2007 GB 9706.27-2005 GB9969.1 GB/T14710-1993 YY0466-2003 |
|